Warehouse 01 Floor 1 Inbound Pilot

This directory is a preparation package. Do not enable the pilot during preparation.

Prepared state

  • FORTUCKY_INBOUND_PILOT_ENABLED=false
  • Legacy remains the only inbound writer.
  • The pilot scope is fixed to warehouse 01, floor 1. A different configured warehouse or floor disables pilot routing.
  • No database script in this directory is run automatically.
  • Outbound, relocation, other floors, and other warehouses are unchanged.

Later maintenance-window order

  1. Confirm the current WMS is stopped and retain its known-good IDEA configuration.
  2. Run install-layer1-inbound-pilot.cmd "lpc:." "FT546-wms".
  3. Run check-layer1-inbound-pilot.cmd "lpc:." "FT546-wms" and retain the output.
  4. Start the candidate with FORTUCKY_INBOUND_PILOT_ENABLED=false and verify normal Legacy operation.
  5. Only after a separate approval, restart with FORTUCKY_INBOUND_PILOT_ENABLED=true.

Immediate application rollback

Stop the candidate and restart it with FORTUCKY_INBOUND_PILOT_ENABLED=false. This restores Legacy-only routing. The procedure can remain installed because the disabled application never calls it.

After the pilot is disabled, optional database cleanup is:

rollback-layer1-inbound-pilot.cmd "lpc:." "FT546-wms" CONFIRM_LAYER1_PILOT_ROLLBACK

The rollback SQL rejects every database except FT546-wms and drops only the procedure carrying the package ownership marker.